關(guān)于醫(yī)用內(nèi)窺鏡的故障檢修您了解多少呢?為了讓您更好更順利的使用該設(shè)備,下面
內(nèi)窺鏡維修公司為您講解:
How much do you know about the troubleshooting of medical endoscope? In order to let you use the equipment better and more smoothly, the endoscope maintenance company will explain to you:
在組織管理方面:如劃分技術(shù)專門的組,一專多能;計算儀器復(fù)雜系數(shù),合理分擔(dān);分科室或儀器到人,包干負(fù)責(zé);組織故障會診;總工程師負(fù)責(zé)制等。
In terms of organization and management: such as dividing technical teams into specialized ones, with one specialty and multiple abilities; Calculate the instrument complexity coefficient and share it reasonably; Each department or instrument shall be responsible for the personnel; Organize fault consultation; Chief engineer responsibility system, etc.
在人才培養(yǎng)方面:如引進(jìn)和培養(yǎng)相結(jié)合,逐步形成人才梯隊,在職提高和外送培訓(xùn)相結(jié)合,基礎(chǔ)理論深入和技術(shù)提高相結(jié)合等。
In terms of talent training: such as the combination of introduction and training, the gradual formation of talent echelon, the combination of on-the-job improvement and outward training, the combination of in-depth basic theory and professional technology improvement, etc.
在維修程序方面:先了解儀器故障起因,熟悉儀器的工作原理,然后運用自己掌握的基礎(chǔ)理論知識針對儀器的電路圖分析故障產(chǎn)生的可能部位,逐步檢測排查,從中找出故障的真正部位,后修復(fù)或更換故障部件,并完成局部或整機(jī)調(diào)試。
In terms of maintenance procedures: first understand the cause of the instrument fault, be familiar with the working principle of the instrument, then use the basic theoretical knowledge that you have mastered to analyze the possible parts of the fault according to the circuit diagram of the instrument, and then gradually detect and troubleshoot, find out the real parts of the fault, then repair or replace the faulty parts, and complete the local or complete machine commissioning.
故障部位一般機(jī)械部分比電路部分多;強電部位比弱電部位多;高溫部分比低溫部分多;電源部分比主體部分多,傳動部位比靜止部位多,按插部位比固定部仿多,阻容器件比半導(dǎo)體器件多,模擬電路比數(shù)字電路多等客觀規(guī)律,檢測方法有敲擊法、直觀法、測量法、比較法,替換法、變溫法,信號追蹤法、信號輸入法、前后合追法、負(fù)載分離法等實用方法。
Generally, the mechanical part is more than the circuit part; There are more strong current parts than weak current parts; The high temperature part is more than the low temperature part; The power part is more than the main part, the transmission part is more than the stationary part, the insertion part is more than the fixed part, the resistance and capacitance device is more than the semiconductor device, the analog circuit is more than the digital circuit, and other objective laws. The detection methods include knocking method, visual method, measurement method, comparison method, replacement method, temperature change method, signal tracking method, signal input method, front and back tracking method, load separation method and other practical methods.
維修方法:應(yīng)遵循先詢問,后診斷;先直觀,后測查;先,后局部:先傳動,后電路;先獨立,后整機(jī);先外圍,后芯片;先控制,后數(shù)據(jù);先定性,后定量等辯證關(guān)系的原則。更多的相關(guān)內(nèi)容就來我們網(wǎng)站
http://wufangbu88888.cn進(jìn)行咨詢吧!
Maintenance method: first inquire, then diagnose; First visual, then inspection; First comprehensive, then partial: first drive, then circuit; First independent, then complete machine; First peripheral, then chip; Control first, then data; The principle of dialectical relations such as first qualitative, then quantitative. Come to our website for more relevant content http://wufangbu88888.cn Consult!