相關(guān)要求在每次重復(fù)使用前對(duì)內(nèi)窺鏡進(jìn)行質(zhì)量控制,此外,
內(nèi)窺鏡設(shè)備維修人員提醒您,須保存每一條內(nèi)鏡每次重復(fù)使用的記錄,包括要有關(guān)于功能測(cè)試的文件,在硬式內(nèi)鏡再處理過(guò)程中有一些重要的步驟。
It is required to control the quality of the endoscope before each reuse. In addition, the maintenance personnel of the endoscope equipment remind you that you must keep the records of each reuse of the endoscope, including the documents about the function test. There are some important steps in the reprocessing process of the hard endoscope.
重要的步驟經(jīng)常被遺忘,所造成的延誤和混亂為致命,比如讓患者在手術(shù)臺(tái)上,焦急地等待著一條新內(nèi)窺鏡。在這些程序中,指定機(jī)構(gòu)負(fù)責(zé)重復(fù)使用的器械,其中包括功能檢測(cè)。
Important steps are often forgotten, and the resulting delay and confusion are fatal. For example, patients are waiting anxiously for a new endoscope on the operating table. In these procedures, the designated agency is responsible for the reuse of the device, including functional testing.
總之對(duì)內(nèi)鏡的整個(gè)再處理過(guò)程以及具體怎樣使用它完全負(fù)責(zé)。如果出錯(cuò)太多,監(jiān)查人員就會(huì)來(lái)查找問(wèn)題所在。
In short, I am fully responsible for the whole reprocessing process of endoscope and how to use it. If there are too many errors, the supervisor will find the problem.
為了確保質(zhì)量以及合規(guī),根據(jù)法律要求,在整個(gè)再處理過(guò)程中要有義務(wù)做好記錄。做好記錄將在之后有特殊情況需要進(jìn)行追溯時(shí)非常有幫助,不管是因?yàn)椴划?dāng)或是需要召回。
In order to ensure quality and compliance, it is necessary to keep records during the whole reprocessing process according to legal requirements. Keeping records will be very helpful when there are special circumstances that need to be traced later, whether it is due to improper disinfection or recall.
如果不能證明已經(jīng)進(jìn)行過(guò)檢查和測(cè)試,出了問(wèn)題就會(huì)被追責(zé)。因此,在清洗后,要檢查與內(nèi)鏡相關(guān)的所有零部件是否受到腐蝕、表面是否受損、碎屑和污染。硬式內(nèi)鏡壽命通常是因?yàn)槭褂迷斐傻睦匣褪軗p而終結(jié)。
If it cannot be proved that the inspection and test have been carried out, it will be held accountable for any problems. Therefore, after cleaning, all parts related to the endoscope should be checked for corrosion, surface damage, debris and contamination. The service life of rigid endoscope is usually terminated due to aging and damage caused by use.
不要忘了人們是不能隨著時(shí)間的推移去發(fā)現(xiàn)內(nèi)鏡的逐漸變化的,但是機(jī)器可以。如果在檢查過(guò)程中發(fā)現(xiàn)損壞就可以立刻將受損的內(nèi)鏡送去維修公司或及時(shí)進(jìn)行更換。即使在清洗和過(guò)程中非常仔細(xì),內(nèi)鏡中的光學(xué)玻璃表面和機(jī)械部件上仍有可能存有污漬,仍需要進(jìn)行再次清洗和。
Don't forget that people can't discover the gradual changes of endoscopy over time, but machines can. If damage is found during the inspection, the damaged endoscope can be immediately sent to the maintenance company or replaced in time. Even if the cleaning and disinfection process is very careful, there may still be stains on the optical glass surface and mechanical parts in the endoscope, which still need to be cleaned and disinfected again.
內(nèi)窺鏡重復(fù)使用時(shí)要進(jìn)行功能檢測(cè)的相關(guān)內(nèi)容就講解到這里了,您對(duì)此有怎樣的疑惑或者問(wèn)題就來(lái)我們網(wǎng)站
http://wufangbu88888.cn咨詢!
That's all about the function detection when the endoscope is reused. If you have any doubts or questions about it, please come to our website http://wufangbu88888.cn consulting service