內(nèi)窺鏡設(shè)備如今在醫(yī)療行業(yè)中頻繁的應(yīng)用,使用時(shí)間久了自然而然的會(huì)出現(xiàn)一些小問(wèn)題,比如說(shuō)突然出現(xiàn)了設(shè)備送水送氣不順暢了,那么這是怎么回事呢?下面來(lái)講講吧。
Endoscope equipment is now frequently used in the medical industry. After a long time of use, there will naturally be some small problems, such as the sudden emergence of the equipment to send water and air is not smooth, so what is going on? So let's talk about it.
內(nèi)窺鏡設(shè)備送水送氣不順暢的原因有幾個(gè),比如:水瓶接口的O型圈損壞、老化、丟失,將水倒入送風(fēng)管。水瓶蓋內(nèi)的O型圈丟失或損壞,導(dǎo)致氣體流出水平儀。除此之外,水太滿(mǎn)或水瓶沒(méi)有擰緊。主機(jī)氣泵未開(kāi)啟,內(nèi)窺鏡與主機(jī)未按相應(yīng)要求連接牢固,無(wú)法將空氣輸送內(nèi)窺鏡管路。內(nèi)窺鏡使用后不能及時(shí)床邊清洗,或前內(nèi)窺鏡未及時(shí)徹底清洗,導(dǎo)致蛋白凝固。不合理的清潔保養(yǎng)造成供水、供氣按鈕損壞。
There are several reasons why the water and air supply of endoscope equipment is not smooth, such as damage, aging and loss of the O-ring of the water bottle interface, and pouring water into the air supply pipe. The O-ring inside the bottle lid is missing or damaged, causing gas to flow out of the level. In addition, the water is too full or the bottle is not tightened. The air pump of the main machine is not opened, and the endoscope and the main machine are not firmly connected according to the corresponding requirements, so the air cannot be transported to the endoscope pipeline. The endoscope can not be cleaned bedside in time after use, or the endoscope is not cleaned thoroughly in time before disinfection, resulting in protein coagulation. Unreasonable cleaning and maintenance caused water supply and gas supply button damage.
那針對(duì)原因,我們使用設(shè)備時(shí)應(yīng)該要怎么處理?檢查水瓶接口和水瓶蓋內(nèi)的O型圈,看是否損壞或丟失。如果出現(xiàn)相應(yīng)的問(wèn)題,需要及時(shí)更換。及時(shí)擰緊水瓶以免漏氣,水瓶?jī)?nèi)的水不要太滿(mǎn),需要儲(chǔ)存適量的空氣。打開(kāi)氣泵,內(nèi)窺鏡與主機(jī)的連接需要穩(wěn)定。如果送風(fēng)按鈕和供水按鈕損壞,需要及時(shí)更換。內(nèi)窺鏡應(yīng)用后,需要立即在床邊進(jìn)行清潔。清洗時(shí),應(yīng)將轉(zhuǎn)爐與給水、供氣管道一起清洗,管道的供氣和供水應(yīng)重復(fù)15秒。床頭清洗完成后,需要立即發(fā)送設(shè)備,可以去室進(jìn)行。
So what should we do when we use the equipment for that reason? Check the bottle connector and o-ring inside the lid for damage or missing. If any problem occurs, replace it in time. Tighten the water bottle in time to avoid air leakage, the water in the bottle is not too full, need to store the right amount of air. Open the air pump, the connection between the endoscope and the host machine needs to be stable. If the air supply button and water supply button are damaged, replace them in time. Bedside cleaning is required immediately after endoscope application. When cleaning, the converter should be cleaned together with the water supply and gas supply pipeline, and the gas supply and water supply of the pipeline should be repeated for 15 seconds. After cleaning the head of the bed, it is necessary to send the equipment immediately and go to the disinfection room for disinfection.
內(nèi)窺鏡設(shè)備維修事項(xiàng)也要提前做好工作才行,操作人員應(yīng)該及時(shí)發(fā)現(xiàn)故障,通過(guò)系統(tǒng)分析,找出發(fā)生故障的原因,掌握排除故障的方法,恢復(fù)內(nèi)窺鏡設(shè)備的技術(shù)狀態(tài)非常重要。
Endoscopic equipment maintenance matters should also do a good job in advance, the operator should find out the fault in time, through system analysis, find out the cause of the fault, master the method of troubleshooting, restore the technical state of endoscopic equipment is very important.
內(nèi)窺鏡設(shè)備送水送氣不順暢是怎么回事?以上就是相關(guān)內(nèi)容的講解了。如果您對(duì)此還有疑問(wèn)的話(huà),不妨點(diǎn)擊網(wǎng)址
wufangbu88888.cn直接來(lái)聯(lián)系我們進(jìn)行咨詢(xún)!